Using Automatic Logging
|
|
To set up the
auto log feature go to the "Data Logging" drop down menu and click
on "Automatic
Logging" . Once the automatic logging dialog is open you will
You can set up
the auto logging feature many different ways.
The simple
method has a drop down menu with a very log list of optional engine
parameters to choice from . Once you have picked which engine
parameter you
would like to trigger your data logging you can then
pick from a list of three options .
"Engine Parameter" > grater than your entered value .
"Engine Parameter" = equal to your entered value .
"Engine Parameter" < less than your entered value .
If you want to
make a custom condition that will turn your logging on or off
then
you can select the "Expression" option and enter a equation .
EXAMPLE : If
you want to start logging with a engine RPM over 2500 and a TPS
position over
50% then you would use this formula rpm < 2500 && tps <
50.
If you choose
your start logging parameters as automatic but leave your stop
logging in manualmode
then it will start once your engine reaches your set
parameters and stay logging
until you shut it of manually or shut the engine off .